Doors
- Doors
Size Tested | AAMA Rating | Air | Water | Uniform Load | Size Tested | Uniform Load | Impact Rated | |
600.600HD | no structural testing | |||||||
623.620PD | 192″ X 96″ | C50 | 0.22 cfm/ft^2 | 7.5 psf | 75.0 psf | 192″ X 96″ | DP50 | YES |
96″ x 96″ | DP50 | 0.11 cfm/ft^2 | 7.50 psf | 75.0 psf | 96″ x 96″ | DP50 | YES | |
144″ x 96″ | C50 | 0.11 cfm/ft^2 | 7.50 psf | 75.0 psf | 144″ x 96″ | DP50 | YES |
Thermal | ||||
Clear/Clear | Clear/LowE/Argon | |||
“U” Factor | SHGC | “U” Factor | SHGC | |
600.603 | n/a | n/a | 0.232 | n/a |
623.620 | n/a | n/a | 0.233 | n/a |
Windows
- High Performance Windows
Size Tested | AAMA Rating | Air | Water | Uniform Load | Size Tested | Uniform Load | Impact Rated | |
179.043DH | 48″ x 72″ | 55 | 0.11 cfm/ft^2 | 8.25 psf | 90.0 psf | 54″ x 77″ | 90.00 psf | YES |
44″ x 63″ | 55 | 0.11 cfm/ft^2 | 8.25 psf | 120.0 psf | ||||
54″ x 77″ | “+50/-50” | 0.03 cfm/ft^2 | 7.5 psf | 75 psf | ||||
179.043HS | 108″ x 60″ | C40 | 0.12 cfm/ft^2 | 9.75 psf | 60 psf | NO | ||
108″ x 48″ | HSR/RPG50 | 0.13 cfm/ft^2 | 9.75 psf | 75.0 psf | ||||
72″ x 60″ | HSR/RPG45 | 0.11 cfm/ft^2 | 9.75 psf | 67.5 psf | ||||
72″ x 48″ | C65 | 0.11 cfm/ft^2 | 9.75 psf | 112.5 psf | ||||
179.043CA | no testing for this model | NO | ||||||
179.000PW-001 | 64″ x 84″ | C70 | 0.01 cfm/ft^2 | 12.00 psf | 105.0 psf | 64″ x 84″ | 65 | YES |
50″ x 63″ | C80 | 0.01 cfm/ft^2 | 12.00 psf | 120.0 psf | 50″ x 63″ | 55 | YES | |
72″ x 72″ | 65 | 0.03 cfm/ft^2 | 12.0 psf | 97.5 psf |
Thermal | ||||
Clear/Clear | Clear/LowE/Argon | |||
“U” Factor | SHGC | “U” Factor | SHGC | |
179.043DH | 0.35 | 0.37/0.33/0.30 | n/a | n/a |
179.043HS | 0.34 | 0.31/0.28/0.25 | n/a | n/a |
179.043CA | no testing for this model | |||
179.000PW-001 | 0.34 | 0.41/0.37/0.33 | n/a | n/a |
Size Tested | AAMA Rating | Air | Water | Uniform Load | Size Tested | Uniform Load | Impact Rated | |
176.043SH | 54″ x 77″ | HLC/LCPG70/ +70 -80 | 0.04 cfm/ft^2 | 10.5 psf | 105-127.5 | 54″ X 77″ | 105-127.5 | YES |
176.043SS | 111″ x 63″ | HLC/LCPG70/ +70 -85 | 0.02 cfm/ft^2 | 10.5 psf | 105-127.6 | 111″ x 63″ | 105-127.6 | YES |
74″ x 63″ | HLC/LCPG70/ +70 -86 | 0.02 cfm/ft^3 | 10.5 psf | 105-127.7 | 74″ x 63″ | 105-127.7 | YES | |
176.00PW | 72″ x 84″ | 90/100 and 80+/- | 0.02 cfm/ft^2 | 15.0 psf | 180 psf | 72″ x 84″ | 180 psf | YES |
72″ x 63″ | 100/80 | 0.02 cfm/ft^3 | 15.0 psf | 187.5 psf | 72″ x 63″ | 187.5 psf | YES |
Thermal | ||||
Clear/Clear | Clear/LowE/Argon | |||
“U” Factor | SHGC | “U” Factor | SHGC | |
176.043SH | 0.33 | 0.30/0.27 | n/a | n/a |
176.043SS | 0.3 | 0.28/0.25 | n/a | n/a |
176.000PW | 0.31 | 0.33/0.30 | n/a | n/a |
Size Tested | AAMA Rating | Air | Water | Uniform Load | Size Tested | Uniform Load | Impact Rated | |
400.400DAW-TT-001 | 48″ x 71″ | CW100 | 0.02 cfm/ft^2 | 15 psf | 150.0 psf | 48″ x 71″ | 100/105 | YES |
400.400PW | 60″ x 72″ | 135/135 | 0.02 cfm/ft^2 | 15 psf | 135/135 | 60″ x 72″ | 135/135 | YES |
72″ x 72″ | 115/135 | 0.02 cfm/ft^2 | 15 psf | 115/135 | 72″ x 72″ | 115/135 | YES | |
48″ x 72″ | 100/100 – 100/100 | 0.05 cfm/ft^2 | 15 psf | 150.0 psf | 48″ x 72″ | 150.0 psf | YES |
Thermal | ||||
Clear/Clear | Clear/LowE/Argon | |||
“U” Factor | SHGC | “U” Factor | SHGC | |
400.400DAW-TT-001 | 0.26 | 0.26 | n/a | n/a |
400.400PW | 0.24 | 0.30/0.27 | n/a | n/a |
Size Tested | AAMA Rating | Air | Water | Uniform Load | Size Tested | Uniform Load | Impact Rated | |
145.093SH-011 | 40″ x 60″ | R50 | .11 cfm/ft^2 | 7.50 psf | 75.0 psf | 44″ x 84″(142.094SH-003) | 97.5 | YES |
36″ x 66″ | R50 | 0.11 cfm/ft^2 | 7.50 psf | 75.0 psf | 64″ x 84″ (142.094SH-003) | 120 | YES | |
145.095DH-009 | 48″ x 75″ | R20 | 0.11 cfm/ft^2 | 5.25 psf | 30.0 psf | 48″ X 72″ (142.194DH) | 75 | YES |
40″ X 63″ | R35 | 0.11 cfm/ft^2 | 5.25 psf | 60 psf | ||||
142.094HS | 76″ x 60″ | R/PG15 | 0.13 cfm/ft^2 | 5.25 psf | 22.5 psf | NO | ||
72″ x 48″ | 25 | 0.2 cfm/ft^2 | 4.5 psf | 37.5 psf | ||||
145.095SS | 84″ x 60″ | LC25 | 0.07 cfm/ft^2 | 5.25 psf | 37.5 psf | 73″ x 62″ | 50/50 | YES |
72″ x 48″ | LC35 | 0.07 cfm/ft^2 | 5.25 psf | 82.5 psf | ||||
120″ x 60″ | LC25 | 0.1 cfm/ft^2 | 3.75 psf | 52.5 psf | ||||
96″ x 60″ | LC30 | 0.14 cfm/ft^2 | 4.50 psf | 52.5 psf | ||||
143.191CA | 37″ x 75″ | 70 | 0.01 cfm/ft^2 | 12 psf | 4/14/2000 | 37″ x 76″ | 70/70 | YES |
143.148CA | 36″ x 60″ | 25 | 0.03 cfm/ft^2 | 9.75 psf | 37.5 psf | |||
72″ x 60″ | 20 | 0.04 cfm/ft^2 | 12 psf | 30 psf | ||||
145.000PW | 80″ x 84″ | R-PG60 | 0.01 cfm/ft^2 | 9.00 psf | 90.0 psf | 48″ x 63″ | 80 | YES |
48″ x 84″ | RPG60 | 0.01 cfm/ft^2 | 9.0 psf | 90 psf | ||||
60″ x 60″ | C80 | 0.01 cfm/ft^2 | 12.0 psf | 120.0 psf | ||||
72″ x 48″ | C80 | 0.01 cfm/ft^2 | 12.0 psf | 120.0 psf |
Thermal | ||||
Clear/Clear | Clear/LowE/Argon | |||
“U” Factor | SHGC | “U” Factor | SHGC | |
145.093SH-001 | 0.48 | 0.63/0.56 | 0.26 | 0.27 |
145.093DH | 0.32 | 0.36/0.32 | n/a | n/a |
145.093HS | 0.47 | 0.61/0.55 | 0.25 | 0.26 |
143.095SS | 0.46 | 0.61/0.55 | 0.26 | 0.24 |
143.191CA | 0.25 | 0.18/0.17 | n/a | n/a |
145.093PW | 0.31 | 0.37/0.34 | n/a | n/a |